Residential and light-commercial heating and cooling. Every job starts with a room-by-room load calculation — because the size of the old unit is not a specification.

Steel pipework running along a brick basement wall.

01 — What we are

A mechanical contractor, not a box swapper.

Plenty of the systems we are called out to replace were never broken. They were the wrong size on the day they went in — too big, short-cycling, stripping humidity out of the air in August and running the burner ragged in January. A system that is two tons oversized cannot be repaired into being the right size.

So we measure. Every install begins with a Manual J load calculation, room by room, windows and insulation and orientation counted. It takes an afternoon. It is the difference between equipment that lasts eight years and equipment that lasts twenty.

  • Furnaces
  • Heat pumps
  • Air conditioning
  • Ductwork
  • Air sealing
  • Light commercial

02 — The work

Three things, done properly.

Furnaces & heat pumps

Cold-climate heat pumps that still make heat at 5°F, and sealed-combustion gas furnaces where a heat pump is the wrong answer. We will tell you which one your house is, and why.

96% AFUE Variable speed Cold-climate rated

Air conditioning

Matched condenser and coil — never a condenser bolted onto whatever coil was already there. New line set on every changeout, brazed under flowing nitrogen so the inside of the pipe stays clean.

Up to 20 SEER2 Matched coil New line set

Ductwork & sealing

The best equipment in the county cannot fix a duct system losing a third of its air into a crawlspace. We design to Manual D, seal with mastic rather than tape, and prove it with a blower door.

ACCA Manual D Mastic-sealed Blower-door tested

03 — The specification

What is actually in the quote.

A watchmaker prints the movement, the case and the crystal on the card, because the details are the argument. This is ours. Every line is on every proposal we write, in this order.

A manifold gauge set mounted on a wall, red and blue refrigerant hoses crossing beneath brass valves.
Charge verified by weight and subcooling
Load calculation
ACCA Manual J, room by room, measured on site. Not estimated from square footage and never copied off the nameplate of the unit being replaced.
Duct design
ACCA Manual D for new trunk and branch runs, with static pressure measured before and after. If the existing ducts cannot carry the airflow, we say so before you buy equipment, not after.
Equipment
Model numbers written out in full — condenser, coil and air handler as a matched set, with the AHRI reference number so you can look up the rating yourself.
Refrigerant lines
New line set on every changeout. Brazed under flowing nitrogen, pressure-tested, and evacuated to below 500 microns with the gauge left on to prove it holds.
Commissioning
Charge set by weight and confirmed by subcooling. Airflow measured. Every reading written on a commissioning sheet that stays taped inside the air handler door.
Warranty
Ten years on our labor, registered manufacturer warranty on the equipment. Both in writing, both handed over on the last day.
Not included
Electrical service upgrades, gas line resizing and structural work, if the job needs them. We price them separately and plainly rather than burying them.
A mechanical room wall of parallel steel pipe runs and a gas meter.

04 — The rule we work to

The old unit’s size is not a specification. It is a guess somebody else made.

Replacing like for like just buys the same problem again, with a new warranty on it. If the original was oversized — and on older houses around here it often was — the replacement will be too, unless somebody actually measures.

A technician brazing a joint with a torch, a copper refrigerant cylinder and hand tools on the bench beside him.
Brazing under flowing nitrogen

05 — Method

The part nobody sees is the part that fails.

When copper is brazed with air still inside it, the heat grows a black oxide scale on the inner wall. That scale breaks loose later, travels with the oil, and takes out a compressor three summers after anyone remembers the install. Flowing nitrogen through the line while brazing prevents it entirely. It costs a few dollars of gas and ten minutes.

That is the whole method, applied to everything: do the invisible parts properly, because they are the ones that decide how long the visible parts last.

Evacuation

Below 500 microns, isolated, and watched to confirm it holds — not pumped for a fixed number of minutes and hoped for.

Condensate

Trapped, sloped and run to somewhere it can actually drain, with a float switch that shuts the system down before a ceiling does.

06 — How a job runs

Four visits, and you know the price after the first.

  1. 01

    Survey

    An afternoon in the house. Rooms measured, insulation and windows recorded, ducts inspected, static pressure read.

  2. 02

    Proposal

    The specification above, filled in for your house, with model numbers and a fixed price. Usually within three days.

  3. 03

    Install

    One to three days for most homes. Floors covered, old equipment hauled away, the site left swept.

  4. 04

    Commission

    Readings taken and written down, the thermostat explained, the paperwork and both warranties handed over.

07 — Estimate

Tell us about the house.

Survey and proposal are free and carry no obligation. We work in Morgantown and the surrounding county.

Telephone
(304) 555-0148
Hours
Monday–Friday, 7:00 AM–4:30 PM
Emergency service for existing customers, year round
Service area
Morgantown and Monongalia County, West Virginia

Concept form — it does not send